1.
J Saudi Heart Assoc ; 36(1): 14-22, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38566902

RESUMEN

Objectives: This retrospective study sought to determine the feasibility of transcatheter atrial septal defect device closure in patients less than 15 kg, as well as to assess complication rates and the reasons for unsuccessful device closure. Background: In general, the risks associated with transcatheter atrial septal defect device closure are believed and reported to be relatively low, but the evidence stems from trials involving adults and older children. Current guidelines do not recommend atrial defect closure in device closure in children <15 kg, due to limited data available for feasibility and safety of device closure in this group of patients. Methods: Retrospective review of all patients who underwent elective transcatheter closure of ostium secundum atrial septal defect between September 2013 to February 2022. We excluded all children above 15 kg, as well as those with complex congenital heart defects. Major and minor complications were predefined and indications for referral were evaluated. Results: We identified 81 patients meeting criteria with a median procedural age of 3 years (1 year-8 years), and median weight of 12 kg (4-15 kg). Successful device closure was achieved in 95.1% (77/81) and in 4.9% (4/81), the procedure was aborted. There was 1 major (1.2%) and 1 minor (1.2%) complication, total complication rate (2.4%). 100% of the referrals had right heart enlargement and exertional dyspnoea, 18.5% had recurrent lower respiratory tract infection and 9.9% had failure to thrive. Rate of resolution of residual shunt was 95.1%. at post-procedure day 1 and 98.8% at post-procedure 3 and 6 months respectively. Conclusions: Percutaneous atrial septal defect closure can be done effectively and safely in symptomatic children weighing less than 15 kg in experienced centres. However, deferral for closure until the historically established timeline of around 4-5 years of age should be strongly considered in asymptomatic children.

2.
J Am Coll Cardiol ; 81(1): 49-64, 2023 01 03.
Artículo en Inglés | MEDLINE | ID: mdl-36599610

RESUMEN

BACKGROUND: The status of vascular lesion treatment using percutaneous intervention (PI) in Takayasu arteritis (TAK) remains unresolved. OBJECTIVES: This study sought to develop PI strategies appropriate for TAK. METHODS: A prospectively maintained single-center database of TAK PI procedures from 1996 to 2022 was analyzed retrospectively. Obstructive lesions were treated by elective stenting (using bare or covered stents), balloon angioplasty (BA), or cutting-balloon angioplasty (CBA), with adjunctive stenting for suboptimal BA or CBA results. PIs were repeated in restenotic lesions until sustained success was obtained. Aortic or peripheral aneurysms and spontaneous aortic dissections were treated with covered stents or endografts. Immunosuppressive therapy, started before PI, was continued long term. RESULTS: A total of 942 patients underwent PI to treat 2,450 arterial lesions (2,365 stenoses or occlusions, 85 aneurysms or dissections) in 630 subclavian or axillary, 586 renal, 463 aortic, 333 carotid, 188 mesenteric, 116 iliac, 71 coronary, and 63 other arteries; 3,805 PIs were performed (1.55 PIs per lesion; range 1-7 PIs per lesion). Early success was obtained in 2,262 (92.3%), and late success in 1,460 (84.5%) of 1,727 lesions with a median of 39 months (IQR: 15-85 months) of follow-up. Repeated PIs increased late success in obstructive lesions from 48.6% to 83.3%. A total of 1,687 elective stenting lesions achieved 88% late success with 1.49 PIs per lesion; covered stents (1.18 PIs per lesion) restenosed less than bare stents (1.51 PIs per lesion; P < 0.001). A total of 183 (36%) of 513 BA-treated lesions had good outcomes without adjunctive stenting; 122 CBA-treated lesions had 19% dissections and 8% ruptures or pseudoaneurysm formations. Aneurysms or dissections had 91.3% late success after PI. A total of 472 complications occurred in 415 (17%) lesions; 375 (79%) were resolved. CONCLUSIONS: Most vascular lesions in TAK can be effectively, safely, and durably treated using predominantly stent-based PI strategies.


Asunto(s)
Aneurisma , Angioplastia de Balón , Arteritis de Takayasu , Humanos , Arteritis de Takayasu/diagnóstico , Arteritis de Takayasu/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Aneurisma/complicaciones , Stents
3.
Pol J Radiol ; 87: e348-e353, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35892072

RESUMEN

Purpose: Excessive accumulation of free fatty acids in the coronary arteries can lead to coronary artery disease (CAD). Quantification of epicardial adipose tissue (EAT) and pericardial adipose tissue (PAT) is beneficial to understand its relationship with CAD, hypertension (HT), and diabetes. Material and methods: This retrospective study included 54 patients who underwent CT coronary angiogram using a multidetector row CT scanner. The EAT and PAT volumes from cardiac images were quantified using Image J software. The severity of CAD was graded using the CAD-RADS score. Results: Twenty-nine patients had no CAD, 21 patients had significant CAD, and 4 patients had insignificant CAD. Out of 21 patients with significant CAD, 14 had involvement of multiple coronary arteries. The EAT and PAT volumes were higher in patients with HT, DM, CAD-present group and significant-CAD-present group, but this was not statistically significant except the PAT volume with respect to diabetes. Significant correlation was found between EAT volume and calcium score (p = 0.035) and between EAT volume and total cholesterol level (p = 0.017). Significant differences in the EAT volumes were found in different CAD-RADS categories in the right coronary artery (RCA). From the threshold values, it was observed that CAD can develop in LAD even at lower of EAT and PAT volumes. Conclusions: Quantification of EAT and PAT volumes is beneficial in understanding its relationship with the presence and severity of coronary artery disease and its risk factors.

4.
J Endovasc Ther ; 29(6): 893-903, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35021904

RESUMEN

PURPOSE: To achieve accurate rotational orientation and the axial position of unconstrained triple-fenestrated physician-modified endografts upon deployment in the aortic arch during total arch thoracic endovascular aortic repair (TA-TEVAR). MATERIALS AND METHODS: Following a detailed study of reconstructed computerized tomography angiography images of patients' arch anatomy, customized, sealable fenestrations with radio-opaque margins are created onsite on Valiant Captivia (Medtronic) endografts, transposing the arch branch ostial anatomic interrelationship onto the endograft precisely. Radio-opaque figure-of-8 markers, indicating the 12 o'clock (superior) position, are attached to the endograft on the surface and brought up to the surface under the endograft cover during resheathing. Resheathing without any twist in the endograft is achieved by lining up the welds in each endograft stent segment in a straight line. The fluoroscopic working view for arch endograft delivery and deployment is the left anterior oblique view that is orthogonal to the plane of the arch, which, in turn, is the right anterior oblique view in which parts of a stiff indwelling guidewire in the ascending and descending aorta precisely overlap. During introduction in the working view, the endograft delivery system is rotated in the descending thoracic aorta so that the 12 o'clock figure-of-8 markers are viewed on the edge and situated at the outer aortic curvature; continued advancement into the arch without any further rotation will ensure superior orientation of the figure-of-8 markers and, consequently, correct endograft rotational orientation. Proper axial endograft positioning requires locating the left common carotid artery (LCCA) fenestration just proximal to a taut externalized LCCA-femoral guidewire loop marking the posterior limit of the LCCA ostium. After endograft deployment during rapid cardiac pacing, the target arch branches are cannulated through their respective fenestrations using hydrophilic 0.035-inch guidewires that are externalized via distal sheaths to create femoral-arch branch (through-and-through) loops over which covered fenestrated stents are introduced and deployed. RESULTS: This technique was used successfully in 31 consecutive patients undergoing TA-TEVAR; systemic blood pressure was obtained in all arch branches immediately after endograft deployment, indicating adequate blood flow. All arch branches were successfully cannulated and stented. CONCLUSION: This system enables accurate deployment of unconstrained triple-fenestrated arch endografts simply and reliably during TA-TEVAR.


Asunto(s)
Aneurisma de la Aorta Torácica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Prótesis Vascular , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/métodos , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/métodos , Diseño de Prótesis , Resultado del Tratamiento , Stents
5.
Indian Heart J ; 73(5): 656-659, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34627589

RESUMEN

Patent foramen ovale closure (PFO) is an underutilized therapy, and our study explored the challenges and feasibility of PFO closure in the Indian setting. Eighty patients with Embolic Stroke of Undetermined Source (ESUS) were screened by transcranial Doppler (TCD) for PFO. Twenty-nine patients underwent successful closure. High-risk features of a long tunnel, inter-atrial septal aneurysm, and large defect were present in 31%, 28%, and 59%. Transcranial Doppler had a sensitivity and specificity of 78% and 53% (p = 0.02) to detect PFO. Anticoagulation was withdrawn in 85% of patients post closure. Two patients had residual shunts at follow-up of 19 (9,34) months.


Asunto(s)
Foramen Oval Permeable , Aneurisma Cardíaco , Dispositivo Oclusor Septal , Accidente Cerebrovascular , Estudios de Factibilidad , Foramen Oval Permeable/diagnóstico , Foramen Oval Permeable/epidemiología , Foramen Oval Permeable/cirugía , Humanos , India/epidemiología , Recurrencia , Resultado del Tratamiento
6.
Catheter Cardiovasc Interv ; 97(5): 815-824, 2021 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-32294309

RESUMEN

OBJECTIVES: To study the safety of stent avoidance, frequency of change in management decisions, and its cost implications while using a fractional flow reserve (FFR)-guided treatment strategy for intermediate-grade coronary artery stenosis. BACKGROUND: The impact of FFR in guiding management decisions and its cost implications has not been studied after imposition of a ceiling on stent prices by the Government of India. METHODS: In 400 patients with 477 intermediate-grade coronary lesions for whom coronary intervention was planned, functional assessment using FFR was done. Incidence of the primary composite endpoint (major adverse cardiac event [MACE], cardiac death, myocardial infarction, objective evidence of ischemia, and target vessel revascularization) in the stent avoided subset was compared with the stented group at follow-up. Micro-costing analysis was done using a computed model with current stent and FFR wire prices. RESULTS: The overall incidence of MACE was 4.9%, 0.9% in the stent-avoided subset and 6.9% in stented group (p = 0.04, comparing the latter two) at a median follow-up of 21 months (interquartile range 12-31 months). Serious adverse events occurred only in 1% of patients receiving adenosine. The average cost saving was Indian rupees (INR) 51,847 [United States Dollar (USD) 746] per patient, resulting in total savings of INR 15,813,379 (USD 227,530). Cost savings persisted but were lower by 36% (INR 18,613/USD 268 per patient) after the ceiling of stent prices. CONCLUSION: FFR-guided percutaneous coronary intervention (PCI) strategy is safe and cost-effective in countries where majority of patients self-finance their health care, resulting in stent and PCI avoidance in approximately one in three patients referred for coronary angioplasty.


Asunto(s)
Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Reserva del Flujo Fraccional Miocárdico , Intervención Coronaria Percutánea , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/terapia , Humanos , Intervención Coronaria Percutánea/efectos adversos , Resultado del Tratamiento
7.
Ann Pediatr Cardiol ; 13(3): 238-240, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32863661

RESUMEN

Cardiac tumors in neonates and infancy are one among the many known congenital cardiac diseases. Although fetal cardiac tumors are rare, there is increased detection because of expertise in echocadiographic examination. Rhabdomyomas are the most common cardiac tumors among infants and children. Here, we describe twin neonates who had multiple cardiac tumors. This kind of presentation appears to be a very rare situation.

8.
Ann Pediatr Cardiol ; 13(1): 95-97, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32030045

RESUMEN

Congenital mitral stenosis (MS) is a spectrum of anomalies that result in functional and anatomic obstruction of inflow into the left ventricle. Mitral arcade is one of the varieties of congenital MS where there is an abnormal development of chordae tendineae, resulting in stenosis, regurgitation, or both. Here, we describe the case of a mitral arcade in a child, which was diagnosed on echocardiography and confirmed with other imaging modalities.

10.
Indian Heart J ; 70(2): 308-315, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29716712

RESUMEN

BACKGROUND: Catheter based treatment has gained wide acceptance for management of patent ductus arteriosus (PDA) ever since its introduction. Percutaneous closure in adults can be challenging because of anatomical factors including large sizes, associated pulmonary arterial hypertension (PAH) and co-morbidities. This study aimed to provide comprehensive contemporary data on the safety and efficacy of percutaneous device closure of PDA in adult and adolescent population at a large referral center. METHODS: This single-center retrospective analysis included 70 patients (33 adolescents and 37 adults) who underwent successful percutaneous device closure of PDA between January 2011 and February 2017.Baseline patient demographics, clinical characteristics, procedural and device related variables, and immediate outcomes during hospital stay were recorded. Patients were followed up for residual shunt and complications. RESULTS: Of 70 PDA device closure cases, 71.4% were females; the mean age was 23 years (range:10-58years). Devices used were 4-Cook's detachable coils, 64-occluders (ADO-I and II, Lifetech, Cardi-O-Fix), 1-vascular plug and 1-ventricular septal occluder device. Device success was achieved in all including those with very large PDAs. At 24-h post-procedure, the success rate of transcatheter intervention was 95.7%. At 6-months follow up, complete closure was observed in all (mean follow up duration-531days). In patients with severe PAH, significant immediate and sustained reduction of the mean pulmonary pressure was observed(77mmHg to 33mmHg;P=0.014). No procedure-related complications including death, device embolization and stenosis of aorta or pulmonary artery occurred. CONCLUSIONS: In contemporary practice, percutaneous device closure is an effective and safe treatment option for adolescent and adult PDA patients.


Asunto(s)
Cateterismo Cardíaco/métodos , Procedimientos Quirúrgicos Cardíacos/métodos , Conducto Arterioso Permeable/cirugía , Dispositivo Oclusor Septal , Adolescente , Adulto , Niño , Conducto Arterioso Permeable/diagnóstico , Conducto Arterioso Permeable/fisiopatología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
11.
J Radiol Prot ; 38(2): 511-524, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29380743

RESUMEN

The radiation dose from complex cardiac procedures is of concern due to the lengthy fluoroscopic screening time and vessel complexities. This study intends to assess radiation dose based on angiographic projection and vessel complexities for clinical protocols used in the performance of percutaneous transluminal coronary angioplasty (PTCA). Dose-area product (DAP), reference air kerma (K a,r) and real-time monitoring of tube potentials and tube current for each angiographic projection and dose setting were evaluated for 66 patients who underwent PTCA using a flat detector system. The mean DAP and cumulative K a,r were 32.71 Gy cm2 (0.57 Gy), 51.24 Gy cm2 (0.9 Gy) and 102.03 Gy cm2 (1.77 Gy) for single-, double- and triple-vessel PTCA, respectively. Among commonly used angiographic projections, left anterior oblique 45°-caudal 35° reached 2 Gy in 55 min using a low-dose fluoroscopy setting and 21 min for a medium-dose setting. Use of a low-dose setting for fluoroscopic screening showed a radiation dose reduction of 39% compared with a medium-dose setting.


Asunto(s)
Angioplastia Coronaria con Balón , Angiografía Coronaria , Dosis de Radiación , Adulto , Anciano , Angioplastia Coronaria con Balón/instrumentación , Femenino , Humanos , Masculino , Persona de Mediana Edad
12.
Indian Heart J ; 68 Suppl 2: S11-S14, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-27751258

RESUMEN

Balloon mitral valvotomy (BMV) performed by the conventional transfemoral approach can be difficult or even impossible in the presence of structural impediments such as severe kyphoscoliosis, gross cardiac anatomic distortion and inferior vena caval anomalies. A 25-year-old woman with severe thoracolumbar kyphoscoliosis due to poliomyelitis presented with symptomatic rheumatic mitral valve stenosis. After the failure of transfemoral BMV, the procedure was attempted from the right jugular access, using a modified septal puncture technique. The left atrium was entered from the jugular access and the mitral valve was crossed and dilated successfully using over the wire balloon technique. Transjugular BMV is an effective alternative in patients with kyphoscoliotic spine that preclude transfemoral approach. The detailed technique used for the procedure, its advantages as well as the other percutaneous treatment options are also discussed.


Asunto(s)
Valvuloplastia con Balón/métodos , Cateterismo Venoso Central/métodos , Cifosis/complicaciones , Estenosis de la Válvula Mitral/cirugía , Cardiopatía Reumática/cirugía , Escoliosis/complicaciones , Adulto , Ecocardiografía , Femenino , Humanos , Venas Yugulares , Cifosis/diagnóstico , Estenosis de la Válvula Mitral/complicaciones , Estenosis de la Válvula Mitral/diagnóstico , Radiografía Torácica , Cardiopatía Reumática/complicaciones , Cardiopatía Reumática/diagnóstico , Escoliosis/diagnóstico , Índice de Severidad de la Enfermedad
13.
J Appl Clin Med Phys ; 17(3): 433-441, 2016 05 08.
Artículo en Inglés | MEDLINE | ID: mdl-27167263

RESUMEN

Coronary angiography (CA) procedure uses various angiographic projections to elicit detailed information of the coronary arteries with some steep projections involving high radiation dose to patients. This study intends to evaluate radiation doses and estimated risk from angiographic projections during CA procedure performed using novel flat detector (FD) system with improved image processing and noise reduction techniques. Real-time monitoring of radiation doses using kerma-area product (KAP) meter was performed for 140 patients using Philips Clarity FD system. The CA procedure involved seven standard projections, of which five were extensively selected by interventionalists. Mean fluoroscopic time (FT), KAP, and reference air kerma (Ka,r) for CA procedure were 3.24 min (0.5-10.51), 13.99Gycm2 (4.02-37.6), and 231.43 mGy (73.8-622.15), respectively. Effective dose calculated using Monte Carlo-based PCXMC software was found to be 4.9mSv. Left anterior oblique (LAO) 45° projection contributed the highest radiation dose (28%) of the overall KAP. Radiation-induced risk was found to be higher in females compared to males with increased risk of lung cancer. An increase of 10%-15% in radiation dose was observed when one or more additional projections were adopted along with the seven standard projections. A 14% reduction of radiation dose was achieved from novel FD system when low-dose protocol during fluoroscopy and medium-dose protocol during cine acquisitions were adopted, compared to medium-dose protocol.


Asunto(s)
Cateterismo Cardíaco/métodos , Angiografía Coronaria/instrumentación , Angiografía Coronaria/métodos , Fluoroscopía/métodos , Órganos en Riesgo/efectos de la radiación , Monitoreo de Radiación/instrumentación , Femenino , Humanos , Masculino , Dosis de Radiación , Radiografía Intervencional
14.
J Clin Diagn Res ; 10(2): OD01-2, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27042501

RESUMEN

Neurological manifestations such as seizures although rare are well recognized presentations of cardiac arrhythmias. Almost always, such events are primarily generalized in nature leading on to loss of consciousness. Rarely however, cardiac seizures can manifest with focal neurological events. We report a case of a sexagenarian who presented with recurrent focal seizures with secondary generalization, who was misdiagnosed and treated as seizure disorder; only a careful history and focussed investigations helped in realising a precise diagnosis.

16.
Ann Pediatr Cardiol ; 9(1): 72-4, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27011698

RESUMEN

We report a rare case of ruptured right sinus of valsalva into the left ventricle (LV). Transthoracic echocardiography showed a marked turbulent flow from the right aortic sinus to the LV. We describe a novel technique of closure of this defect with duct occluder, involving the formation of an arterio-arterial loop, without resorting to the usual arteriovenous loop.

19.
BMJ Case Rep ; 20152015 Nov 24.
Artículo en Inglés | MEDLINE | ID: mdl-26604236

RESUMEN

A direct right pulmonary artery to left atrial fistula is a rare congenital condition in which patients usually present with isolated cyanosis in the absence of abnormal cardiovascular findings. We report the percutaneous closure of such a defect in a young woman who presented with severe cyanosis. This was achieved without making a conventional venovenous loop and was performed using an Amplatzer vascular plug. We believe, in patients with a suitable anatomy, closure with vascular plug without a venovenous loop should be the method of choice for treating this malady in view of the technical ease.


Asunto(s)
Arteria Pulmonar/anomalías , Arteria Pulmonar/cirugía , Dispositivo Oclusor Septal , Fístula Vascular/cirugía , Adulto , Femenino , Atrios Cardíacos , Humanos , Arteria Pulmonar/diagnóstico por imagen , Radiografía , Fístula Vascular/diagnóstico por imagen
20.
J Med Phys ; 40(1): 24-8, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26150684

RESUMEN

Flat panel detector (FPD) technology in interventional cardiology is on the increase due to its varied advantages compared to the conventional image intensifier (II) systems. It is not clear whether FPD imparts lower radiation doses compared to II systems though a few studies support this finding. This study intends to compare radiation doses from II and FPD systems for coronaryangiography (CAG) and Percutaneous Transluminal Coronary Angioplasty (PTCA) performed in a tertiary referral center. Radiation doses were measured using dose area product (DAP) meter from patients who underwent CAG (n = 222) and PTCA (n = 75) performed using FPD angiography system. The DAP values from FPD were compared with earlier reported data using II systems from the same referral center where the study was conducted. The mean DAP values from FPD system for CAG and PTCA were 24.35 and 63.64 Gycm(2) and those from II system were 27.71 and 65.44 Gycm(2). Transition from II to FPD system requires stringent dose optimization strategies right from the initial period of installation.